Doornbos Estates #1 Production Facility

Parent Companies:
EPA Facility ID:
100000211264
Other ID:
Facility DUNS:
0

Location:

Address:
4 miles northeast of Longville, LA
Longville, LA 70652
County:
BEAUREGARD
Lat / Long:
30.630, -93.180 (Get map)
Method:
GPS - Unspecified
Description:
Loading Area Centroid
Horizonal accuracy:
2 m
Horizontal reference datum:
World Geodetic System of 1984
Source map scale:

Owner/Operator:

Name:
Union Gas Operating Company
Phone:
(281) 397-0077
Address:
14505 Torrey Chase Blvd., Ste. 205
Houston, TX 77014
Foreign Address:

Person responsible for RMP implementation:

Name:
Randy Lowry
Title:
President
Email:

Emergency contact:

Name:
Randy Lowry
Title:
President
Phone:
(281) 397-0077
24-hour phone:
(281) 397-0091
Ext or PIN:

Other contacts:

Facility (or company) email:
Facility phone:
Facility (or company) URL:

Safety:

Local Emergency Planning Committee:
Full-Time Equivalent Employees:
0
Covered by OSHA PSM:
No
EPCRA section 302:
No
CAA Title Air Operating Permit:
No
CAA Permit ID#:
OSHA Star/Merit Ranking
No
Last Safety Inspection Date:
Inspecting Agency:
Never had one
Using Predictive Filing:
No

Processes:

NGL Storage
RMP ID:
1000017256
CBI claimed:
No
Program Level:
1
NAICS:
Crude Petroleum and Natural Gas Extraction (211111)
Chemical name
CAS#
Quantity (lbs.)
CBI
Flammable Mixture
00-11-11
31,075
No
Public OCA Chemical
0
No

RMP Preparer:

Name:
Steve Roland
Address:
30902 Carrington Dr.
Magnolia, TX 77354
Foreign Address:

Phone:
(281) 252-6148

Latest RMP Submission:

Date:
May 3, 2010
Type:
First-time submission
Reason:
Registered:
No
RMP ID:
1000013782

Deregistration:

Date:
Effective Date:
Reason:
Source terminated operations
Other Reason:

2. Toxics: Worst-case

None

3. Toxics: Alternative release

None

4. Flammables: Worst-case

Some Risk Management Plan information is not provided in the available RMP data. You need to make an appointment at an EPA Reading Room In order to get access to details from the Off-Site Consequence Analysis (OCA) such as:

Instructions on how to make an EPA appointment can be found here.

Public OCA Chemical (in NGL Storage)
CBI claimed:
No
Model used:
EPA's RMP*Comp(TM)
Passive mitigation
considered:
  • None
not considered:
  • Blast walls

5. Flammables: Alternative release

None

6. Five-year accident history

No Registered Accidents

7. Prevention: Program level 3

No Prevention Program level 3

8. Prevention Program level 2

No Prevention Program level 2

9. Emergency response

Facility In Community Plan:
No
Facility Own Response Plan:
No
Specific Facility Response Plan:
No
Inform. Procedures in Response Plan:
No
Emergency Care in Response Plan:
No
Plan Review Date:
Response Training Date:
None
Local Response Agency:
Local Response Agency Phone:
(337) 725-3381
Subject To - OSHA EAP:
No
Subject To - OSHA HAZWOPER:
No
Subject To - CWA:
No
Subject To - RCRA:
No
Subject To - OPA:
No
Subject To - State EPCRA:
No
Subject To - Other:

Executive Summary

Union Gas Operating Company (Union) owns and operates the Doornbos Estates #1 Production Facility. The Doornbos Estates #1 Production Facility receives production from area oil and gas wells via flowline. The production is treated to separate gas, water and condensate. The gas is further processed through a cryogenic process involving the rapid temperature and pressure change via a Joule-Thompson (JT) valve which condenses the lighter hydrocarbons, including methane, ethane, propane, butane and pentane, to condense forming a Natural Gas Liquid (NGL) product. The NGL product is stored in a pressurized bullet tank with a volume of 18,000 gallons and operating pressure of ~150 psi.

A total rupture of the 18,000 gallon NGL tank resulting in a vapor cloud explosion would pose the worse-case scenario for the Doornbos Estates #1 Production Facility. The 18,000 gallon tank has been evaluated for total tank rupture using the RMP*Comp offsite consequence analysis resulting in a distance to endpoint of 0.3 miles. No public receptors are within a 0.3 mile radius of the NGL tank. The worst-case scenario would not affect anyone within the endpoint of the off-site consequence analysis. Therefore, this RMP has been evaluated for a Program 1 level RMP under 40 CFR 68. The Doornbos Estates #1 Production Facility is located in a remote area and is not normally occupied.

The facility has no accident history to report. Should an emergency involving the Doornbos Estates #1 Production FacilityA?s NGL system occur, it is UnionA?s policy to notify the Beauregard Parish Fire District #2 and request that they respond to the emergency. This policy has been discussed with the fire department.